AMC3200DF Series



 


The AMC3200DF Series
 converter features in dual frequency excitation. The reduced noise and improved signal to noise ratio make it more idea for slurry measurement in various industries such as papermaking and chemistry. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting. It's equipped with bluetooth, HART and MODBUS communication functions
.
FEATURES


 Dual Frequency Excitation Method  
 Three line LCD display Flow Rate / Totalizer  
 Accuracy of +/-0.4% value of reading  
 Bi-directional flow measurement, current and pulse output  
 Explosion Proof, Ex d (ia) llC T3-T6  
 Bluetooth / MODBUS / HART communication  
 Converter can be rotated at Four directions for easy installation

 
SPECIFICATION

Excitation:Keypad:
Dual Frequency Excitation3 Internal keys for programming 
Display:and display control
3 Lines LCD with illuminationData Storage:
Line 1Operation parameters and totalizer
8 Digit totalizer for forward flowfigures are stored by EEPROM for more
8 Digit totalizer for reverse flowthan 10 years
8 Digit totalizer for differenceLow Flow Cutoff:
Line 20-9.9%
4 Digit flowrate / velocity / % / mA / HzDamping:
Line 30-99 Seconds
Parameter / Query / Clr tot / Query LOGDensity Setting:
Alarm, Guidance0.001-9.999 g/cm3
Totalizer UnitSelf Diagnosis:
t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal,The following error message are
Mgal, bbl, ft3, a-ft  displayed if failure occurs
Time Unit-Abnormal sample
sec, min, hour, day-Pulse width
Measuring Range:-Overanged output
Min. 0-0.15 m/s-Internal error
Max. 0-15 m/s-Overflow
Accuracy:-Empty pipe
+/-0.4% of reading (Velocity>=1.0 m/s)Cable Entry:
+/-0.002 m/s (Velocity: 0.3...­1.0 m/s)Standard: M20  Option: 1/2" NPTF
Repeatability:Protection Class:
+/-0.2% of readingIP67, Explosion Proof, Ex d (ia) llC T3-T6
Current Output:Ambient Temperature:
4-20 mA (Isolated)-25~65 oC
LoadMaterial:
Max. 500 Aluminum Alloy
Pulse Output:Power Supply:
Open collector90-260 VAC, 50/60 Hz
Rating24 VDC +/-10% (Option)
3-30 VDC, 50 mA Max. Power Consumption:
Pulse Rate:6-8 W (Dependent on sensor size)
1)Scale pulse (mL/Pusle, L/Pulse, Other)Weight:
2)Frequency: 0-5000 Hz4.5 kg
Pulse Width:Mounting:
50% of band widthBracket on 2" pipe
Alarm:AMF Collocation Type:
High / Low with open collector outputAMF900, AMF601, AMF500
RatingSensor Size:
3-30 VDC, 50 mA Max. DN50-DN450
Communication:
Bluetooth (Android) Standard
RS485 (MODBUS Protocol) Standard
HART signal (Compatible) Optional
[Read More...]


APF830 Series






APF830 Series

The APF830 series is a positive displacement meter designed with a pair of tooth profile helical rotors, which displays totalizer with a mechanical pointer and provides 4-20 mA or pulse output. It has the advantages of no pulsation, low noise, high accuracy, high reliability, large measuring scope and strong environment adaptability.
APF830 series helical rotar flowmeter could be used in commercial measurement and engineering management control in petrochemical, metallurgical, electronics and other industries.
FEATURES

 Pipe size : 25-300 mm (1"-12") 
 Fluid viscosity up to 2000 cP 
 High measurement accuracy, wide flow range and good repeatability 
 Helical rotors rotate evenly, with little vibration and long lifetime 
 Insensitive to viscosity variations in the measured liquid 
 6 Digit totalizer + 2 digit pointer 
 High accuracy +/-0.5% of reading (or +/-0.2% of reading) 
 4-20 mA and pulse output
 
SPECIFICATION

Size:Process Connection:
25, 40, 50, 80, 100, 150, 200, 250, 300 mmFlange
Measuring Range:Flange Type:
0.5-950 m3/hrJIS 10K / JIS 20K / JIS 40K
Accuracy:ANSI 150# / ANSI 300# / ANSI 600#
+/-0.5% of reading (Standard)DIN PN10 / PN16 / PN25 / PN40
+/-0.2% of reading (Option)Mechanical Register:
Repeatability:Totalizer (Non-Reset)
+/-0.1% of reading (Standard)6 Digit + 2 Pointer
+/-0.07% of reading (Option)Totalizer (Resettable)
Material:Upper Counter
Body & Cover & Flange6 Digit + 2 Pointer (Non-Resettable)
Cast Steel / S.S. 304 / S.S. 316Lower Counter
Helical Rotor4 Digit + 2 Pointer (Resettable)
Cast Iron / S.S. 304 / S.S. 316Resolution:
O-Rings0.1 Liter (25 mm)
Viton1 Liter (40-80 mm)
Shaft Sleeve10 Liter (100-300 mm)
Ball / Ceramic BearingCurrent Output:
Register Housing4-20 mA (2 wire)
Aluminum AlloyLoad
Max. Viscosity:Rohm=(VDC-9) * 50
0.3-400 cP (Standard)Pulse Output:
400-2000 cP (Option)Open Collector (3 Wire, Unscaled pulse)
Operating Temp. :Rating
-10~120 oC (-10~80 oC with Output)11-26 VDC, 50 mA Max. 
-10~120 oC with Output (Option)Cable Entry:
-10~250 oC (Option)M20 (Standard) / 1/2" NPTF (Option)
Ambient Temperature:Protection Class:
-25~60 oCIP65
Max. Pressure:Intrinsically Safe, Eex ia IIC T6 
63 kgf/cm(<=DN100)Explosion Proof, Ex d IIB T6 
25 kgf/cm(>=DN150)Optional:
Painting:Heating Jacket (Hot oil or Steam)
Body, RegisterStrainers, T-Type or Y-Type
Red lead + Alia BlueStrainer with Air Eliminator, Flange End
Housing
Red lead + Alia Blue
[Read More...]


 