AFC365 Series






AFC365 Series

The AFC365 Series Flow Computer is a microprocessor-based instrument designed to measure compensated flow in industrial environment.The AFC365 incorporates the Ideal Gas / Steam / Natural Gas compensation.The Backlit LCD display simplifies programming and clearly indicates all parameters as well as engineering units.
FEATURES

 DIN Size (96 * 96 mm), 320 * 240 Pixels, 4-line LCD display
 Built-in 8 MB memory, applicable to long-term data record
 Common input signal: mA, RTD, Frequency etc.
 High Accuracy +/-0.1% of Reading
 4-20 mA / Relay / RS485 output
 Ideal Gas/ General Gas / Steam / Energy formula
 24 VDC Aux. power supply available for 2 wires system
 Fascia Sealing for IP65 (NEMA 4X) water tight
 Hourly / Daily / Monthly / Yearly history data record
 
SPECIFICATION


Number of Inputs:Display:
3 Channels3.5" Mono-screen LCD with Backlit
Flow Function:Response Time:
Input100 ms
4-20 mA / Frequency (0-10 kHz)Keypad:
Display6 keys for programming and display
5 Digits flowrate with decimal pointcontrol
13 Digits totalizer with decimal pointEngineer Unit:
Accuracy21 different engineering units
+/-0.1% of readingParameter Protection:
Temperature Function:2 Password entries (6 Digits) for
One or Two point (Energy calculator)Supplier and User
InputLogging Rate:
PT100 / 4-20 mA1-60 minutes Per Data
DisplayRecording Capability:
4 digits temperature value with decimal point30 days (1 Data / minutes)
Accuracy1800 days (1 Data / Hour)
+/-0.1 oCStorage Memory:
Pressure Function:8 MB (on board)
InputRecycling Mode:
4-20 mA Newest data overwrites oldest data
DisplayProtection Class:
5 Digits pressure value with decimal pointNEMA4 / IP65 (Fascia sealing)
AccuracyWeight:
+/-0.1% of reading0.5 kg Maximum
Calculation Function:Dimensions:
Ideal Gas, Temperature & Pressure Comp.96 mm (W) * 96 mm (H) *150 mm (D)
General Gases, Temp & Pressure Comp.Ambient Temperature:
Natural Gas, NX-192  Formula-10~60 oC
Saturated Steam, Superheated SteamAmbient Humidity:
Liquid Mass, Density calculation10-85% RH (5-40 oC)
Alarm Types:Power Supply:
High & Low alarm, Incr. & Decr. alarm85-260 VAC, 50/60 Hz
Aux. Power Output:Vibration Test:
12 VDC / 24 VDC, 100 mA for Flow Transmitter10-60 Hz,10 m/s2  for 3 hours
24 VDC, 100 mA for Temperature TransmitterPower Consumption:
24 VDC, 100 mA for Pressure Transmitter<= 10 W
Output:Communication:
4-20 mA, Load 750 W  * 1 pointRS485 (MODBUS Protocol)
Relay, 3 A / 250 V * 1 pointParameter Storage:
Operation parameters are stored by 
EEPROM for more than 10 years





 