Measuring Principle: | Low Level Cutoff: |
Ultrasonic Sound | 0.000-1.000 Meter |
Measuring Range: | Dead Band: |
Level | 0.35 m Max. |
0-3 Meter | Bean Angle: |
Flow Rate | 6 o |
0-120000 m3/s | Keypad: |
Accuracy: | 4 Key with tactile action |
+/-0.25% of Full Scale | Response Time: |
Repeatability: | Less than 1 second |
+/-0.1% of reading | Ambient Temperature: |
Material: | -20~60 oC |
Ultrasonic Tube | Mounting: |
ABS | G2" (Standard) / Flange end (Optional) |
Sensor Head | Max. Cable Length: |
Polyurethane (Standard) / ETFE / PTFE | 50 m |
Housing | Power Consumption: |
ABS (Remote Version) | Less than 3 W |
Low copper cast aluminum alloy with | Power Supply: |
polyurethane (Compact Version) | 90-260 VAC, 50/60 Hz (4wires) |
Display: | 18-36 VDC (4wires) |
4 Line LCD with illumination | Data Storage: |
Flowrate | Operation parameters and totalization |
9 Digits with decimal point | date are stored by EEPROM for more |
Totalizer | than 10 years |
9 Digits | Output: |
Level | 4-20 mA |
4 Digits | Load |
Flow Engineer Unit | Rohm= (VDC-12) * 50 W |
m3, Liter | Alarm: |
Level | High / Low / High-High / Low-Low |
Meter / Feet | Communication: |
Time Unit | RS485 (MODBUS) |
Second, Hour | Dimensions: |
Other | Compact |
Signal condition | 130 mm (W) * 230 mm (H) * 180 mm (D) |
Formula: | Separate |
V-notch, Parshall, Palmer-Bowlus | 183.5 mm (W) * 218 mm (H) * 125.5 mm (D) |
Rectangular, Cipolletti, Leopold-Lagco | Weight: |
Sensor Frequency: | 3.5 kg (Compact), 2.2 kg (Remote) |
40 kHz / 1 kHz | Enclosure: |
Temp Compensation: | IP65 (ABS) / IP67 (Aluminum Alloy) |
Built-in to compensate over temperature | Explosion Proof, Ex d (ia) IIB T4 |
range |