Measuring Principle: | Process Temperature: |
Ultrasonic Level Measurement | -40~60 oC (Standard) |
Measuring Range: | -40~100 oC (Optional) |
0-3 m, 0-5 m, 0-10 m, 0-15 m, 0-20 m | Process Pressure: |
0-10 ft, 0-16 ft, 0-33 ft, 0-50 ft, 0-65 ft | -0.8~2.0 bar G |
Display: | Max. Cable Length: |
4 Line LCD with Bargraph (illumination) | 50 Meter (Remote Version) |
Resolution: | Power Supply: |
1 mm / 0.003 ft | 12-36 VDC, 2 wires (Compact) |
Accuracy: | Start-up current 25 mA (Standard) |
+/-0.25% of Full Scale | Start-up current 40 mA (With HART) |
Repeatability: | 12-36 VDC / 85-260 VAC, 4 wire (Remote) |
+/-0.1% of reading | Power Consumption: |
Material: | Less than 3W |
Ultrasonic Tube | Output: |
ABS | 4-20 mA |
Sensor Head | Load |
Polyurethane (Standard) / ETFE / PTFE | Rohm= (VDC-12) * 50 |
Housing | Alarm: |
ABS or Aluminum Alloy (Weather Proof) | High/Low/High-High/Low-Low (Remote) |
Aluminum Alloy (Explosion Proof) | Communication: |
Update Time: | RS485 MODBUS, 4 Wire only (Standard) |
<3 s | Hart Signal (Optional) |
Ambient Temperature: | Temp. Compensation: |
-20~60 oC | Built-in to compensate over temperature |
Relative Humidity: | range |
0-100% RH | Data Storage: |
Sensor Frequency: | Operation parameters and totalization |
40 kHz / 1 kHz | date are stored by EEPROM for more |
Blanking Distance: | than 10 years |
0.35-1.0 m | Dimensions: |
Bean Angle: | Compact (ABS) |
6o | 105 mm (W) * 262 mm (H) * 168 mm (D) |
Keypad: | Compact (Aluminum) |
4 Key with tactile action | 161 mm (W) * 247 mm (H) * 132 mm (D) |
Response Time: | Remote (ABS) |
Less than 1 second | 183.5 mm (W) * 218 mm (H) * 125.5 mm (D) |
Protection Class: | Weight: |
IP65 (ABS) / IP67 (Aluminum Alloy) | 1.0 kg / 2.2 kg (Compact), 2.2 kg (Remote) |
Explosion Proof, Ex d (ia) IIB T4 | |
Installation: | |
G 2" and 20 m sensor is M70 * 2 Standard | |
Flange end (Optional) | |
EMI / RFI Effect: | |
Follow SAMA PMC 33.1 from 20-1000 | |
MHz and for field strengths up to 30 V/m |