Measuring Principle: | Keypad: |
Transit time difference | 16 Key with tactile action |
Pipe Size: | Flow Velocity: |
100-1000 mm | 0.01~+/- 32 m/s |
4"-40" | Resolution: |
Material: | 0.0001 m/s |
Carbon Steel / Stainless Steel 304 | Ambient Temperature: |
Stainless Steel 316 | -20~50 oC |
Process Connection: | Mounting: |
Flange | Wall mounting |
Flange Type: | Max. Cable Length: |
JIS 7.5K / JIS 10K / JIS 20K / JIS 40K | 300 m |
ANSI 150# / ANSI 300# / ANSI 600# | Power Consumption: |
DIN PN10 / PN16 / PN25 / PN40 | Less than 2 W |
Max. Pressure: | Power Supply: |
40 kgf/cm2 | 85-265 VAC 50/60 Hz or 8-36 VDC |
Process Temperature: | Data Storage: |
-20~+110 oC | Operation parameters and totalization |
Display: | figures are stored by EEPROM for more |
4 Line LCD with illumination. | than 10 years |
Flowrate | Output: |
5 Digit with decimal point | 4-20 mA or 0-20 mA or 20-4-20 mA |
Totalizer | Pulse Output: |
8 Digit, Forward, Reverse & Net values. | 1-9999 Hz |
Engineer Unit | Data Logger: |
m3, Liter, US Gallon, Imperial Gallon, | Limitless overwriting in 64 columns |
Million Gallon, Cubic Feet, US Barrels, | (Flowrate, totalizer, time, date included) |
Imperial Barrels, Oil Barrel | Alarm: |
Time Unit | High / Low with buzzer |
Second, Minute, Hour, Day | 5 VDC 1 A / 125 VAC 0.5 A |
Other | Communication: |
Velocity, Date, Time, Signal condition | RS485 (MODBUS) |
Accuracy: | Dimension: |
+/- 1.0% of reading | 235 * 205 * 95 mm |
Repeatability: | Weight: |
+/-0.2% of reading | 1.5 kg (Converter) |
Response Time: | Protection Class: |
Less than 1 second | Converter |
| IP65 |
| Sensor |
| IP68 (Submersible) |