Display
|
:
|
8-Digit totalizer, 6-Digit flow
rate
|
|
:
|
5-Digit Pressure,
5-Digit Temp.
|
|
Display Unit
|
:
|
32 Flow engineering unit
|
|
Keypad
|
:
|
3 Internal keys for programming
|
|
|
and output setting
|
|
Current Output
|
:
|
4-20 mA (2-Wire)
|
|
|
with HART signal (Compatible)
|
|
Load
|
:
|
Rohm= (VDC-12) * 50
|
|
Power Supply
|
:
|
12-32 VDC
|
|
Damping
|
:
|
0-32 Seconds
|
|
Humidity Limit
|
:
|
0-100% Relative Humidity
|
|
Turn on Time
|
:
|
2 Seconds with minimum damping
|
|
Zero Calibration
|
:
|
Automatic zero calibration by press-button
|
|
Cable Entry
|
:
|
M20 Conduit Threads / 1/2" NPT (Female)
|
|
Protection Class
|
:
|
IP67 (Standard)
|
|
:
|
Intrinsically Safe, Eex ia IIC T5 (Standard)
|
|
:
|
Explosion Proof, Ex db IIC T6
|
|
EMI / RFI Effect
|
:
|
Follow SAMA PMC
33.1 from 20-1000 MHz
|
|
|
and for field strengths up to 30 V/m
|
|
Vibration Effect
|
:
|
+/-0.05% of URL per g to 200 Hz in any axis
|
|
Process Connection
|
:
|
1/4"-18 NPT
|
|
:
|
1/2"-14 NPT (with adapter)
|
|
Dimensions
|
:
|
102mm(W) * 188mm(H) * 130mm(D)
|
|
Weight
|
:
|
3.5 kg |