| Size: | Local Display: |
| 15,20,25,40,50,65,80,100,125,150,200 mm | Mechanical Indicator (Standard) |
| Measuring Range: | Digit Display |
| Liquid -1~200000 L/hr | 5 Digit Flowrate |
| Gas -0.03~3000 m3/hr | 8 Digit Totalizer |
| Turndown Ratio: | Current Output: |
| 10:1 (20:1 Optional) | 4-20 mA (2 Wire) |
| Accuracy: | Load |
| +/-2.5% (Standard) | Max. 600  |
| +/-1.5% (Optional) | Pulse Output: |
| Repeatability: | Open collector (Scale pulse) |
| +/-0.8% FS | Rating |
| Material: | 3-30 VDC, 100 mA Max. |
| Tube & Float | Alarm Output: |
| Stainless Steel 304 | 2 point (Open collector) |
| Stainless Steel 316 | Rating |
| Standard Pressure: | 3-30 VDC, 100 mA Max. |
| 40 kgf/cm2 (15-50 mm) | Keypad: |
| 16 kgf/cm2 (65-200 mm) | 3 internal keys for programming |
| Temperature: | and display control |
| 0-100 oC (Standard) | Ambient Temperature: |
| Flange Type: | 0-60 oC |
| JIS 10K / JIS 20K / JIS 40K | Protection Class: |
| ANSI 150# / ANSI 300# / ANSI 600# | IP65 |
| DIN PN10 / PN16 / PN25 / PN40 | Intrinsically Safe, Eex ia IIC T5 |
| Fluid Viscosity: | Explosion Proof, Ex d IIB T6 |
| 300 CP Max. | Housing Material: |
| Communication: | Aluminum Alloy |
| RS485 (MODBUS Protocol) | Cable Entry: |
| HART signal (Compatible) | Standard:M20 Option:1/2"NPTF |
| Data Storage: | Pressure Loss: |
| Operation parameters and totalizer | 0.07-0.7 kgf/cm2 |
| figures are stored by EEPROM for more | Power Supply: |
| than 10 years | 12-36 VDC (2 wire 4-20 mA) |
| Ni-MH Battery (3 years working hours) |