AMC2200 Series






AMC2200 Series

The ALIAMAG AMC2200 Series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting. It is equipped with Bluetooth, HART and MODBUS communication functions.

FEATURES


  • Three-line OLED display Flow Rate / Totalizer
  • Accuracy of +/-0.35% value of reading
  • Bi-directional flow measurement, current and pulse output
  • Large digital display
  • Bluetooth / MODBUS / HART communication

 
SPECIFICATION


Excitation : DC pulsed
Display : 3 Lines OLED
Line 1 : Empty pipe symbol / Alarm / Batch control symbol

: Percentage progress bar /  Message / Clr tot
Line 2 : 11 Digit flowrate / velocity / % / mA / Hz / Tot
Line 3 : 9 Digit totalizer for forward flow

: 9 Digit totalizer for reverse flow

: 9 Digit totalizer for difference

: 11 Digit flowrate
Totalizer Unit : m3, L, mL, gal, Igal, Mgal, ft3, bbl,


a-ft, kg, g, lb, t, Ston, Lton
Time Unit : sec, min, hour, day
Measuring Range : Min. 0-0.15 m/s

: Max. 0-15 m/s
Accuracy : +/-0.35% of reading (Velocity0.5 m/s)

: +/-0.00175 m/s (Velocity<0.5 m/s)
Repeatability : +/-0.07% of reading
Current Output : 4-20 mA (Isolated)
Load : Max. 600 Ω
Pulse Output : Open collector
Rating : 3-30 VDC, 50 mA Max.
Pulse Rate : 1)Scaled pulse (mL/Pulse, L/Pulse, Other)

: 2)Frequency: 0-5000 Hz
Pulse Width : 50% of band width
Alarm : High / Low with open collector output
Rating : 3-30 VDC, 50 mA Max.
Communication : Bluetooth (Android) Standard

: RS485 (MODBUS Protocol) Standard

: HART signal (Compatible) Optional

Keypad : 4 Internal keys for programming


and display control
Data Storage : Operation parameters and totalizer


figures are stored by EEPROM for more


than 10 years
Low Flow Cutoff : 0-9.9%
Damping : 0-99 Seconds
Density Setting : 0.0001-9999.9 kg/cm3
Self Diagnosis : The following error messages are


displayed if failure occurs


-Coil failure


-Power failure


-Overranged Output


-Internal error


-Overflow


-Empty pipe
Cable Entry : Standard: M20  Option: 1/2" NPTF
Protection Class : IP65
Ambient Temperature : -40~70 °C
Material : Aluminum Alloy
Power Supply : 90-260 VAC, 50/60 Hz

: 24 VDC +/-10% (Option)
Power Consumption : 3-17 W (Dependent on sensor size)
Lightening Protector : Module design, easy to replace

: Surge test voltage up to 4 kV
Weight : 1.4 kg
Mounting : Wall mounting









































































































 
Back to top Copyright © 2013 | PT.ALIA TEKNIK All Rights Reserved