ARL5200 Series







ARL5200 Series

ARL5200 series non-contact radar level transmitter based on Frequency Modulated Continuous Wave (FMCW) technology and smart algorithms to maximize measurement accuracy, reliability and signal strength, and enables it to deliver superior measurement reliability with greater signal-to-noise ratio, even in small tanks and challenging fast-filling vessels. Non-contacting radar technology is ideal for a wide range of applications, and is unaffected by process conditions such as density, viscosity, temperature, pressure, Vapours, Conductivity, etc. Ideal for level measurement in complex applications such as liquids, slurries, solids, particles and dust.

FEATURES

  • Unique FMCW radar technology for optimal performance
  • High frequency 80 GHz fast-sweep for application flexibility
  • Measuring range up to 150 m (492 ft), high accuracy of +/-2 mm
  • Non-contact radar, free of wear and pollution
  • Anti-interference of noise, vapor, dust, foam, vacuum, etc.
  • Small beam angle & focused energy to enhance anti-interference ability
  • The measurement of low permittivity constant media is more stable


SPECIFICATION



Measure Principle : Frequency Modulated Continuous Wave(FMCW)
Frequency Range : 77-82 GHz
Measure Range : 0-150 m
Resolution : 1 mm / 0.003 ft
Repeatability : +/-0.5 mm
Accuracy : +/-2 mm…+/-5 mm
Blind Area : 0.01 - 0.03 m
Beam Angle α : 14° / 8° / 6° / 3°
Sensor Update Rate : >1s (Dependent on configuration setting)
Maximum Level Rate : Max. 200 mm/s
Ambient Temp. Effect : +/-1 mm (+/-0.04 in.)  / 10 K
Material

Antenna : PTFE / PEEK
Process Connection : PTFE / S.S. 304 / S.S. 316 / S.S. 316L /


S.S + PTFE
Housing : Aluminum Alloy (Standard)

: S.S. 304 (Option)
O-ring : FKM
Process Connection : Thread (3/4" NPT, G3/4", 1-1/2" NPT,


G1-1/2", G3", 3" NPT)

: Flange (DN50-DN200)

: Universal Flange (DN100-DN200)
Protection Class : IP67

: Explosion Proof, Ex d IIC T6

: Intrinsically Safe, Ex ia IIC T6
Display : 4-6 Digit LCD with Bargraph
Keypad : 4 internal keys for programming
Unit : ft, in, m, cm, mm
Ambient Temperature : -40~80 °C
Process Temperature : -40~260 °C (Max.)
Process Pressure : -1.0~25 bar G (Max.)
Humidity : 0-100% RH, non-condensing
Max. Cable Length : 40 m (For single cavity housing)
Power Supply : 15-28 VDC (2-Wire)

: 24 VDC +/-10% (4-Wire)

: 90-253 VAC, 50 / 60 Hz (4-Wire)
Power Consumption : 22.5 mA / 1W (Max.) (2-Wire)
Current Output : 4-20 mA (2-Wire, 4-Wire)
Load : Rohm=(VDC-15) * 50
Resolution : 1.6 μA
Damping : 0-999 s
Communication : HART signal (Compatible)

: RS485 (MODBUS Protocol)
Data Storage : Operation parameters and totalization


date are stored by EEPROM for more


than 10 years
EMI / RFI Effect : Follow SAMA PMC 33.1 from 20 to 1000


MHz and for field strengths up to 30 V/m
Vibration Resistance : 2g at 10-1000 Hz according to IEC 61298-3
Cable Entry : Standard: M20, Option: 1/2" NPT




























































































































































 
Back to top Copyright © 2013 | PT.ALIA TEKNIK All Rights Reserved