AUF761 Series



AUF761 Series

The AUF761 Series is a fixed-mounted, transit-time ultrasonic Flowmeter. It features factory-mounted transducers that allow it to be flow lab calibrated, reducing or eliminating the random or bias error that can be present in clamp-on style transducer mounting. The meter ensures an accurate, non-invasive measurement of clean homogeneous liquid process, and is widely used in process control and production measurement.

FEATURES

  • 2 lines LCD display with flowrate, totalizer…
  • Stores 720 Hours / 365 Days / 36 Months / 10 Years of Totalizer value
  • Pipe size from DN20-DN1000 mm
  • High accuracy of +/-1% of reading
  • Bidirectional measurement
  • Various output types such as 4-20 mA, pulse, RS485, Alarm
  • With self-calibration function, real-time measurement calibration
  • Accurate and stable measurement
  • The sensor has anti-high temperature and long service life, It can reach to 200 °C in a short time

 
SPECIFICATION



Measuring Principle : Transit time difference
Pipe Size : DN20-DN1000 mm
Flow Velocity : 0.3 ~ +/-12 m/s
Resolution : 0.001 m/s
Accuracy : +/-1% of reading
Repeatability : +/-0.2% of reading
Response Time : Less than 1 second
Process Temperatue : -40~70 °C

: -40~160 °C
Max. Pressure : 100 kgf/cm2
Process Connection : Thread (DN20-DN40)

: Flange (DN20-DN1000)
Flange Type : JIS 10K / JIS 20K / JIS 40K


ANSI 150# / ANSI 300# / ANSI 600#


DIN PN10 / PN16 / PN25 / PN40
Body Material : S.S. 304 / S.S. 316
Housing Material : Aluminum Alloy
Ambient Temperature : -20~50 °C
Protection Class : IP67
Explosion Proof : Ex d IIC T4
IR Remote Control : Intrinsically Safe, Ex ib IIC T6
Keypad : 4 Internal Keys / IR Remote Control
Display : 2 Lines LCD with illumination
Flowrate : 7 Digit with decimal point
Totalizer : 8 Digit, Forward, Reverse & Net values.
Engineering Unit : m3, L, USgal, USbbl, ft3
Time Unit : sec, min, hour, day
Other : Velocity, Date, Time, Signal condition
Max. Cable Length : 100 m
Power Consumption : Less than 2W
Power Supply : 90-260 VAC 50/60 Hz and 24 +/-10% VDC
Data Storage : Operation parameters and totalizer


figures are stored by EEPROM for 


more than 10 years
Current Output : 4-20 mA
Load : Max. 800 Ω
Pulse Output : Scaled Pulse (Open Drain)
Rating : 3-35 VDC, 120 mA Max.
Alarm Output : 2 Relays, Upper and Lower alarm (Option)
Rating : 5A, 30 VDC / 5A, 250 VAC
Communication : RS485 (MODBUS)
Cable Entry : 1/2" NPT (Female) (Standrad)

: M20 * 1.5 (Option)






















































































 